SONYCDP101
Defective crystal1) disc motor would run at power on. 2) no loading orchucking operation. 3) sometimes pause and play, leds would light.4) sometimes drawer would open partly.
SONYXR85
Loading drive belt stretchesLoading drive belt stretches and belt will slip. when thebelt slips the cassette will not load.
SONYXR85
Incorrect part number in manualA tech. ordered a volume control (r/n 502 in the s/m) by theparts number 1-228-735-00 but he received the part 503, instead.
SONYWM10
Cold solder joint on flexible boardUnit stopped rewinding or fast forwarding several secondafter pressing rew or ff button. found cold solder on the flexible boardbetween s901 and r634 as indicated in the diagram.
SONYTCK88B
Unit out of adjustmentDealer complained of gross wow and flutter. verified problem,measured 0.6% jis weighted.
SONYTCK88B
Loose wire between servo board and syscon boardCounter was intermittently not advancing. determined thatic602 derives count from supply reel revolutions using output of q536 andq535 on servo board.
SONYTCFX77
Missing part # in manualThere is no p/n for the capacitor c134, 234 (56pf/500v),which are connected to the r/p head, in the service manual.
SONYTCFX44
Defective relayErratic system control operation. when record button isdepressed, unit will intermittently enter rewind mode after 2-3 sec(record deactivates). results from high resistance of relay contacts.
SONYSPP11
Service manual instructionsP31. lacking a linear detector, i adjust rv2 to energizebase relay.
SONYSPP11
Service manual instructionsP10 of service manual instructs tech. to turn rv6 ccw forfreq. adjustment. it is my belief that it should read rv5, instead.
SONYPSX800
Glue on s/n 800439Intermittent cue up/down malfunction. symptom was no dampingaction. checking output of vert. mfb det coil with scope showed inter-mittent no signal or noisy erratic signal. tan glue on the solderpads of the coil's pcb in the bearing assy caused proble
SONYPSX800
Open lead in s/n 802218Intermittent cue up/down malfunction. symptom was no dampingaction. checking output of vert. mfb det coil with scope showed inter-mittent no signal. an open lead, confirmed withΩmeter was the cause.
SONYKV1222R
Bright picture with retrace linesSet would come on ok when very cold. then after abouta minute, pix would get very bright and have retrace lines.
SONYSTRAV880
No power - unit deadUnit had no power - completely dead.
SONYD7
Insufficient line mutingInsufficient line muting. when pushed, line output wasreduced by better than 40db but not totally muted. signal level slowlydropped off from this point and finally muted completely after severalseconds. the effect was not noticeable on headphone outpu
SONYKX2501
Dead, connector shorted,also replaced q652, q651, and q653Set came in dead. found connector shorted and q653 and q651reading 40Ω between base and emitter (forward and reverse the same).
SONYRM708
No commander operationThis remote commander produced no infrared output. thetransmit indicator did light.
SONYKV2650R
Aft drift, leaky q024When you tuned a station it appeared as if the aft wassearching before it locked in on the strongest portion of the signal.vc was changing slightly before it locked.
SONYKV2649R
No sound, replace ic605No sound in left or right channels.
SONYKV2648R
No bar display, replace shorted q4028No bar display in any function except if volume was atmid-range. picture control would increase or decrease length of bardisplay. with color, hue or brightness there was no bar display.pressing hue, bar was all green. checking input to counter reset,