SONYCDP101
Defective cx-79034Static noise in both channels after 8 to 10 minutes. foundnoise being generated at output of cx-79034.
SONYCDP101
Out of alignmentRumble in audio. checked unit and found no problem. problemcould be in software or playback system. did complete alignment for unit,focus servo slightly out of range. returned to customer.
SONYCDP101
Shorted wire-10 volt line (from cn542 to cn536) was shorted to chassisnear bracket (bottom) to the rear of the sled assy.
SONYXR77
Large distortionUnit produced large distortion during tape operation withoutboard display no. 'dpl -el.
SONYTCK81
High torque measuredAfter installing new take-up arm assembly, forward torquemeasures 55 to 65 q/cn. this may be contributing to tape skew problems,by requiring increased back tension.
SONYTCFX33
Problems around ic501Unit will not lock into play mode and the service manualschematic does not agree with its own board layout in the book andneither agree with the board in the unit. -hq comments: release from play could be initiated by reset pulseor slow oscillator (r-c
SONYTCFX30
Grounding spring neededIntermittent static noise was recorded when humidity levelsare low, erase and r/p heads were eliminated by grounding to chassis thisproblem occurs both on record and playback. -hq comments: 1) please apply grounding spring to erase head as outlinedin ta
SONYTAN88
Open c410The 78v line was reading about 110v on this unit and thesound was distorted. adjusting rt401 had little effect. we found c410to be open and causing the problem.
SONYTAF55
Shorted d406The 15v line was down on this unit. we found d406 shorted(located in regulator circuit).
SONYSTRVX6
Poor connections on q414This unit had a dim display and erratic tuning q414 was found to be poorly soldered on the base and emitter leads.
SONYPSX75
Arm needed adjustmentCantilever of cartridge was being pulled to one side, bendingit eventually also mistracking in one channel, poor dynamic range, etc.
SONYICF2001
Error in pcb diagramWhen rd amp fails, technician replaces q52 as labeled on pcb,diagram is incorrect.
SONYCFS10
End of tape sensor not alignedAs tape moves in play mode - end of tape sensor is not alignedfully with width of tape causing uneven pressure and wrinkling of tape. -hq comments: the crease in the tape is indeed caused by excessivepressure as well as uneven placement of the pu lever
SONYAUDIO GEN
T/n #8467T/n #8467 list ic cx807-f1 and cx807-f3 as applicable to wm-2.however wm-2 uses cx808 on first and second type board an cx887 on thirdtype board. is cx807-f1 and cx807-f3 replacement for cx808 or cx887? -hq comments: cx-807 and cx-808 ics are identical
SONYXR70
Tab adjustment neededIt will not accept tape. cause: eject lever (#387) fails toengage the pin on (#385) when tape is inserted.
SONYXO5
Defective switchThis unit had a bad hum in the phono mode (unless the switchwas pushed in and held in hard). the small switch (muting) along side s2would not make contact unless switch was held in.
SONYWMD6
Foil missingNo ff and rewind. motor started about 2-3 seconds after theplay switch is pressed.
SONYTCM5
Missing parts in s/mThe mechanical layout on page 15 of the s/m is missing parts.
SONYTCFX1010
Broken erase head wireThis unit had a distorted output at the p/b head(non-symetrical sine wave). this of course prevented the auto calibrationcircuit from functioning. we found a broken wire at the erase head to bethe problem.
SONYTC530