Sony Repair Guide: Common Issues and Fixes
Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
SONY | PSX800 | P/n error in s/b | Incorrect p/n listed page 54 of manual - p/n listed8-719-990-03 should be 8-719-910-03. | ||
SONY | PSX600 | Defective ic105 and r170 | Zero balance drifts. | ||
SONY | PSLX500 | Defective socket | The copper sleeves in the socket of the p-mount were pushedall the way back into the tone arm. i have received several reports onthis problem. | ||
SONY | PSFL7 | Pins out of place | The copper sleeves in the p-mount socket were pushed backtoo far to make contact with the pins of the cartridge. | ||
SONY | ICFD11W | Missing ground jumper | When frequency display button was pushed, frequency changedand the station was lost. this was the same problem as reported 2/16/82dk-2-1. it appeared to be a ground loop problem. | ||
SONY | ICFC55W | Leaky c115 | Segment on right channel was not showing proper number. allsegments lite up although a 1 should be shown. found c115 leaky. | ||
SONY | ICFC20W | Defective q4 and q5 | Either q4 was leaky or q5 was open. am on while switch infm position. | ||
SONY | ICF200W | Open r36 | When the unit is turned on after a couple of minutes a clicking noise is heard at the speaker. | ||
SONY | CDP101 | Out of alignment | High-frequency squeal through audio system with cdp-101 inany mode (stop/play/pause). checked completely and looked at output withoscilloscope. no high frequencies were audible. | ||
SONY | CDP101 | Loose right rail on sled | Loose right rail on sled. holder bracket missing. | ||
SONY | CDP101 | Defective cx-79034 | Static noise in both channels after 8 to 10 minutes. foundnoise being generated at output of cx-79034. | ||
SONY | CDP101 | Out of alignment | Rumble in audio. checked unit and found no problem. problemcould be in software or playback system. did complete alignment for unit,focus servo slightly out of range. returned to customer. | ||
SONY | CDP101 | Shorted wire | -10 volt line (from cn542 to cn536) was shorted to chassisnear bracket (bottom) to the rear of the sled assy. | ||
SONY | XR77 | Large distortion | Unit produced large distortion during tape operation withoutboard display no. 'dpl -el. | ||
SONY | TCK81 | High torque measured | After installing new take-up arm assembly, forward torquemeasures 55 to 65 q/cn. this may be contributing to tape skew problems,by requiring increased back tension. | ||
SONY | TCFX33 | Problems around ic501 | Unit will not lock into play mode and the service manualschematic does not agree with its own board layout in the book andneither agree with the board in the unit. -hq comments: release from play could be initiated by reset pulseor slow oscillator (r-c | ||
SONY | TCFX30 | Grounding spring needed | Intermittent static noise was recorded when humidity levelsare low, erase and r/p heads were eliminated by grounding to chassis thisproblem occurs both on record and playback. -hq comments: 1) please apply grounding spring to erase head as outlinedin ta | ||
SONY | TAN88 | Open c410 | The 78v line was reading about 110v on this unit and thesound was distorted. adjusting rt401 had little effect. we found c410to be open and causing the problem. | ||
SONY | TAF55 | Shorted d406 | The 15v line was down on this unit. we found d406 shorted(located in regulator circuit). | ||
SONY | STRVX6 | Poor connections on q414 | This unit had a dim display and erratic tuning q414 was found to be poorly soldered on the base and emitter leads. |