SONYCCDV8
Head cleaning spray causing drum bearings to stickCustomer used gemini products video head cleaner fluid model,cv98 (spray form). after following instructions on can, drum assto stick resulting in poor rotation. -hq comments: as always, we do not recommend that the customer performany type of head cle
SONYAVMT515V
Optional accessory cable for ccd-v110 is unavailableAvm-t515v is listed in ccd-v110 operating instruction underoptional accessories (mini phono to 2 phono). there is no stock of thiscable. -hq comments: these cables are now in stock at kansas city.
SONYICF7600D
Unstable operation in ssb modeIn am ssb mode, very erratic and hard to keep station in tune. -hq comments: there is a s/m supplement which has some ckt. changes tolocal osc. to reduce drift. you might try this change to resolve yourproblem. i will send you a supplement. pls retur
SONYFD3A
Dead, replaced t601, q602 and ic601Q602 leaky and ic601 defective. upon replacing thesecomponents an abnormal raster and sound would appear. there is noapparent video because the 34 volts from switching regulator is absent.inductor t601 may check good (resistance), however it is not ind
SONYPSLX435
No part # for ps-lx435 dust coverCustomer purchased this turntable separately, without dustcover. he wishes to purchase a dust cover. sony burbank needs a p/nreference to back order this for him. -hq comments: see tech. flash a033 dated dec. 15, 1986. part numbersare as follows:x-49
SONYCDP55
Unit gouges disc in circular patternSecond unit with this problem. at first one might suspect afocus problem optical coming up too far. this is being caused by liftpins in the disc table not coming down far enough to clear disc.
SONYKV2782R
Telematic jig adapter, see sb tvp0158r1We need telematic jig adapter for picture tube. can youprovide adapter, or adapter number so we can order? -hq comments: use telematic adapter.yoke 10j 733 settings vert 8, hor 1.2crt 10j 766focus voltage supply fvs-3950 & 10j711 now replaced w
SONYSL5200
No beta hifi recordingNo beta hifi record, but video was being recorded.
SONYSLHF750
Replacement rotation sensor does not workOrdered sensor for rmt-143 received different style part undersame p/n. sensor did not function. -hq comments: please contact kcp and exchange for correct part. contactme if there are any future problems.
SONYSLHF550
Am picture interferenceCustomer located about 1/4 mile from am transmitter operatingat 760 khz. signal is causing interference in picture during playback. -hq comments: try experimenting with a metal shield plate on top ofvideo drum ass
SONYD55
Poor fm receptionFm poor.
SONYKPR4620
Hum in audio, see sb # 284Problem reported from dealer. hum in audio when no volume.two units on floor. volume up all ok. -hq comments: to eliminate buzz, add two 18 kΩ 1/4w resistors(1-247-861-00) to the circuit as shown in service bulletin 284.one 18k between r-193 and c-1
SONYKV25XBR
Picture too widePicture about 3 too wide on each side. if size reduced withwidth control then pin cushion adjustments lost most of their control.
SONYSLHF900
Intermittent auto shut-offSpurious auto shut-off in play. after 45 mins or so take-uptorque would drop below 30 grams and subsequently stall causing auto shut-off.
SONYITA600
Different beep tone levels in out modeDifference in beep levels as described in s/b rad184. per-forming modification had inadequate effect. tape beep approx. 4 db louderthan microprocessor generated one.
SONYPTB100
Replacement part for blower motor not availableMicrofiche shows replacement p/n 9-910-999-35 no longeravailable. -hq comments: computer lists substitute p/n 1-541-164-00 with one instock. please order using this p/n.
SONYCCDV8AFU
Excessive noise from drum bearingNoisy bearing on drum assembly causing excessive noisein pb and rec of video information.
SONYCCDV8
Green spot in pictureSmall green spot in picture - visible under wide range of light levels.
SONYSLHF300
Noise rec in sound and pictureWhen making a recording there was noise in head switching.this caused noise in beta hifi audio and picture had jitter. approx. 7seconds before stopping the recording it would clear up. tape pathlooked correct.
SONYCDXR7
No troubleshooting guideMany units failing after 4 or 5 months of use. failuresvaried and repair time long as no good troubleshooting procedure isavailable. repair time at ssc is about 1 1/2 hrs - longer at asc -hq comments: cdx trouble guide is just about done and will be p