SONYKV1913
Channel not lockAfter 15 minutes, set would go into random timed sound muteand aft drift in short spurts. trouble would only show itself whileconnected to cable system in customer's home (ch. 3) and would not show inservice shop. it was later discovered that ch. 2 is
SONYKV1746R
Dead, replaced d007 and r123Unit would not turn on. found d007 shorted and r123 open.
SONYKV1746R
Dead, replaced ic1 on the "n" boardSet was dead after a thunder storm. remote did not work.relay did not activate when power button was pushed.
SONYKV1746R
Incorrect tuning operationAn attempt is made to program a channel button. althoughreception is ok, there was no memory and once another button is selectedall buttons have lost their program.
SONYKV1741R
Incorrect tuning operationOn this set, complaint was that ch. 5 was hard to tune in andhad a horiz. bar traveling up in pix. inspection revealed that horiz. barwas present on all channels, more noticeable with weak signal. furthertests showed that -11v supply was only -3vdc. d
SONYKV1715R
Incorrect tuning operationWhen turning this unit on it would take 3 to 4 seconds beforeit would select the last channel. then the set displayed a variety ofproblems, the picture had what looked like 60hz ripple in it with lack ofcolor sync. you could select different channels,
SONYKV1711
No pictureThis unit had excessive hum and low b+. it was evident thateither the main filter was bad or the regulator was not working. itbecame obvious that the regulator was not working. careful examinationfound r604 open, although it was not burnt. i have see
SONYKV1547R
No low vhfInspection revealed that vc voltage to tuner would not vary.voltage at pin 22, ic005 was always 4vdc, should be 2.1vdc, with nosignal and set tuned in to vhf low. r074 was not soldered on one end.
SONYKV1547R
Delay in turn on, short ic001/pins 17 & 18I noticed that it took 4 seconds for set to come on. also,when first turned on, response light would not illuminate. collector ofq010 always had a dc level on it and a noisy square wave. pulses werealways present at pin 18, ic001. further inspection
SONYKV1543R
Incorrect tuning operation, open ground d039/r055When set was turned on, it was locked into address position aand would not tune out of this position. any movement of m2 board wouldclear the problem. i then noticed the junction of d039 and r055 which aregrounded at a common point of the pc board, was
SONYKV1513
DeadThis unit kills this if ic after 3 days. replacing ic andinstalling a diode on the vcc of ic, figuring spike entering the part,with no luck. when ic was bad, no sound and picture just snow. voltageson agc pins are all wrong, but when new ic was put in
SONYKV1204
No raster, replaced flybackNo raster or lack of width with flashing lines. after setis on for about 10 to 15 minutes the flyback transformer became hot. part# 1-439-185-00.
SONYKP5040
Test signal interference, r3383 and r3384 connection changeI have two kp-5040s with cross-hatch interference on weaksignal stations - cures suggested in fprs have not helped. if i liftr3383 and r3384 from the 12 volt line and jump them to pin 2 of connectorba-9, and thereby remove voltage from the horizontal cr
SONYKX2501
High pitch squeal, replaced t654When the unit would warm up there was a high pitch squeal.
SONYKX2501
Intermittent horizontal sync, replaced ic501After set got warm about 5 minutes, pix would lose horizontalsync. cooling the ic501 would correct problem.
SONYKX2501
Poor picture, replaced ic103Customer complained of dim picture and excessive audio level.
SONYKV9200
Parts information missingI need assistance with the above unit. it seems that thecircuit was modified or changed during production and this was not shownon the s/m or the two existing supplements. this particular set has adiode d402 and q410, q411 added to the base of q402.
SONYKV2650R
Set would not get some channels, replace ic001Set would not get channels 2,3,7,8 on cable. changed ic001.set would then pick up missing channels, but was missing others. ic waschanged again and would pick up all but channel 13. set was delivered tohome and would receive all channels but 3. set r
SONYKV2648R
Shut down, relay contactsSet comes on and immediately shuts down with loss of b+.found relay contacts spaced too far apart. therefore there was no wipingaction to the contacts at all. i have also found this problem onnumerous other sets.
SONYKV2648R
Dead, replace q602 and r616Set came in dead. found convertor q602 shorted and resistorr616 open.