Search:
Results: 87416

Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYTCFX33
Defective c580The ams solenoid would not consistently engage which resultedin the transport not locking into the play mode. we found the solenoidpre driver not turning on hard enough. c580 had appreciably decreased invalue which did not allow the base of c580 (sol.
SONYTCFX30
Defective reel motorMotor noise was audible through the right channel. this was caused by excessive sparking of one of the brushes in the reel motor.
SONYTCFX4
Defective relayOne channel intermittently records and the sound duringplayback is muddy.
SONYTCFX4
Defective rv104The right meter on this unit stays on with all led'silluminated. we found rv104 (meter adjust pot) open.
SONYTAF70
Defective input jackThis unit had an intermittent hum on the phono input. wefound the input jack to be defective.
SONYSTRVX22
Defective ic301This unit was locked on aux. we found pin 26 of ic301 have asteady 5.4v.
SONYSTRVX6
Defective ic401This unit had no display or tuning action on am/fm.
SONYSTRVX6
DeadDead unit. output transistors were shorted causing pulsepower supply to fail - replaced known defective components restoredoperation but bias current, after adjustment would start to increasecausing outputs to run hot. removed power before damage resul
SONYSTRVX6
Overheating regulatorThe +15v regulator overheated to the point where it burntthe board badly. after replacing the board and modifying according tothe service bulletin we still had a very hot regulator. how can we coolit down?
SONYSTRVX5
Malfunctioning mute circuitUpon turning power off, a slight popping sound through bothspeakers will be heard. by grounding inputs of main amp the popping iseliminated. an imbalance in the decaying time of the positive andnegative supply voltages can be seen on the scope. this r
SONYSTRV25
Aged resistorsThe customer has owned this unit for 16 months and has hadit serviced by an independent servicer 4 times. she said it would playfor a while and then one or both channels would go out and it would stopworking. the relay would kick out.
SONYSRF40W
Defective headphone jackThis unit had good separation and power level but the outputwas distorted. it appeared to be an output problem. further examinationfound the headphone jack defective. although this circuit is a simpleone, this problem was misleading.
SONYSPP11
Open foil traceNo dial out, no dial tone, squelch broken opened base unitand measured voltages. no output from bridge rectifier d-6. found openfoil pattern at output lead of d-6.
SONYSEH310
Poor solder connectionOne channel cuts out intermittently when the space soundfunction was activated.
SONYPSX65
Defective ic106All functions inoperative.
SONYPSX40
Shorting q202We found the dc amp to be open (cracked) as a result of q202shorting - thus applying 18v to the ic.
SONYPSFL1
Noise during operationWhen the turntable moves in or out there is an objectionalclicking sound.
SONYMDRFM5
Part number for wireWire for connecting head-pieces to main cabinet. need blue,orange and grey colored wire that connects switch board to amp in ear-piece. has to be very small wire and stranded wire to last some time. -hq comments: p/n for 10m lengths are as follows:9-9
SONYICFC20W
Defective ic'sWhen power is turned on, display sets to 1:00 am or pm andwill not set time nor alarm functions. when powered up display will onlyindicated flashing dots - no numerial displays.
SONYICF2001
No amAll functions worked except am, found q41 (2sk107) withintermittent lead.