Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Display 1 does not light up (bj539gk) | R347, r348, r114, e pr101 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Very low mic sound | D600, q600, c611, c615 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Sound doesn't turn on | Q421, d204, r204, r205 e r206 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Power supply works but the sound doesn't do anything anymore | Ic201 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Spectrum analyzer (VU of frequencies) does not work | Ic380 e r390 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Does not select disks | R424, ic403, chaves 5451 a 5456 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Engine with wrong rotation | Q1, r4 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Deck motor does not work | Q501, q504 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | No audio | Ic801 | ||
AIWA | NSX-F9, NSX-F98, NSX-F99, NSX-F12, NSX-F15 | Micro doesn't work | 601, j621, q600, ic603 | ||
AIWA | AR295 | Lack of color (green) | R904 | ||
AIWA | AR-205 | Greenish screen (without red) | D902=bav21 | ||
AIWA | NSX-229 | Display almost off | Q105 and the 10r protection resistor connected to it. | ||
AIWA | NSX S222 | If you increase the volume, the device turns off | Found to be defective in the boxes. | ||
AIWA | VXT1400 | When switching to stby raster remains and buzz noise is heared from the speakers | Cause: +b voltage 103 v does not switch-off. remedy: replace defective c541 | ||
AIWA | CX-NS 559LH | Only std led by lit | Q103 open 2sa1235 | ||
AIWA | TV AR 295 RH | Dark square center screen | Swap memory - 24 with 8 -smd | Marco Gasparatto | |
AIWA | Z-R997 | By increasing the volume, the tray opens and rotates the plate. In this case I noticed that when I reached volume 39 the tray opened, and when the analyzer worked at peak + high it also opened. | Ic 380 ba3835s spectrum analyzer | Replace or remove. | joaomvjr |
AIWA | CXNF9HR | Difficulty rotating the disc tray | Jw50 33r resistor changed .check before the belts | Replace | alvaro peralta |
AIWA | CXNV90HR | Does not activate the equalizer buttons in surround | Sale | celio pinheiro dos santos |