Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYCFS220
No tape and/or batteries going deadUnit will have no tape functions and/or will have a constantcurrent draw on battery or ac power supply, even in the off position.this will cause battery to go dead in approximately three days.
SONYPSFL7II
No drawer trnasport +6v ps deadNo +6v supply - all others good. regular circuits ok. fuselink ps409 opens because of a shorted filter cap. voltage rating on the100uf caps are 6.3v that leaves a very small difference between vmax andsupply. if other supplies are found to be shorted
SONYCCDF40
Threading problemWhen unit loads tape, the entrance (tg4) does not go all theway into the drum base track and this causes a tape path problem. this isintermittent. i have three units with the same problem. -hq comments: found loading path was not properly greased. cl
SONYRMP700E
Non active band switching on strav880, no aud/vol controlThis remote will not switch bands on an strav880, but the pre-set buttons work ok. also, it has no audio volume control. this is not adefective unit. -hq comments: you are correct. the sircs codes are different. wesuggest that the ssc program the cu
SONYRME7
Will not operate pslx520, but ok with psfl770The start phono command will not operate a ps-lx520, but worksok with ps-fl770. in both cases, the receiver was a str-av880. the codeoutput by the rme7 for phono start is 01000110 11111. however, the codeoutput by the rme7 for phono start is 01000110
SONYFDL320
No colorNo color. by flexing the pc board, the color would come andgo, an obvious sign of a bad connection or a break. waveform checks re-vealed distortion at tp-31, emitter of q-503. also, the dc level at baseof q-503 would rise to 1-3 vdc when no color disp
SONYPSLX100
Incorrect part subWhen above part number is ordered a sub is received(x-4909-004-1), which is the turntable for a pslx330. this sub will notfit the pslx100. the correct turntable for the pslx100/lx285 is listed inthe manual as the second line entry under item ref. no. 1
SONYTCWR800
Non engagement of head assy on transport assys (tcm 170r)Cam gear reference number 204 will keep on rotating and headassembly will not pull up into cassette. it will reverse direction andtry other side and then stop.
SONYTCWR9ES
Non engagement of head assy on transport assys (tcm 170r)Cam gear reference number 204 will keep on rotating and headassembly will not pull up into cassette. it will reverse direction andtry other side and then stop.
SONYTCWR9ES
Play mode inoperative - deck b(b) deck would not stay in play mode.
SONYTCWR800
Play mode inoperative - deck b(b) deck would not stay in play mode.
SONYBMC110
No filament voltage, no pictureThere was no filament voltage to the tube.
SONYCCDF40
Threading assembly intermittently stops short of loadingThe threading assembly intermitently goes to the fully loadedposition. when this happens, the tape is ejected.
SONYSLHF900
Unit does not accept the cassetteAs the cassette is placed into the cassette compartment, theloading ring assembly goes into the loaded/threaded position. the cass-ette compartment jams and does not accept the cassette.
SONYFDL320
Vertical blanking areaThis unit is one of four which have the same problem. when wereplaced the original lcd, all the replacements have an area near thebottom of the screen resembling insufficient sweep and displays a verticalblanking area. this symptom was not on original
SONYTAN77ES
Meter lamps continue to go badOne row of lamps was out because there was a bad lamp. re-placed bad lamp and about 30 minutes later the other row went out becausea lamp went out in that row. replaced that lamp and then the other rowwent out. help - have three units with this proble
SONYD15
The enter/remain or play function works intermittentlyEnter/remain button or play button does not reach their res-pective switch when it is pushed. the enter/remain or play function doesnot work or intermittently. i have many units which have this problem.
SONYVCT600
Loose top half on panhead assemblyTop half of panhead assembly was loose.
SONYKV1395
Set would not turn on always - sometimes ok for 2-3 weeksSet would turn on intermittently. found sv line wouldsometimes be 3.5 to 4.5v (would vary).
SONYSL2710
Intermittent y signal in pause and betascanIntermittently the luminance signal would disappear. the10.7mhz at pin 3 of ic-14 would come and go intermittently.