Repair Guide: Common Issues and Fixes
Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
SONY | XR7000 | No ams function or audio output | No ams. no auto reverse. pm1 and q801 were both fried. | ||
SONY | ESR11 | Error in manual | This trans will not work. manual should read p/n 729-177-43. -hq comments: you are correct the type description in the schematic isincorrect as well as the part number in the parts list. the correctnumber is 8-729-177-43 for a 2sd774. | ||
SONY | STRAV550 | Dead unit | No oscillator ic351 found 5.5v on base of q803. q803 notturned on so no reset. | ||
SONY | CDPC50 | Mounting of loading gear | The screw and collar do not provide enough support allowingthe gear to lean forward (pivot) preventing the focus block from cyclingcompletely and jamming the tray. | ||
SONY | KV27SXR10 | Pop in r-channel speaker when unit is powered down, r-844 | When the unit is turned off, a single pop resulted in rightchannel speaker only. | ||
SONY | KPR36XBR | Distorted stereo sound, replaced ic-8810 | Unit had distorted, low level audio in stereo mode. noneperformed normal. | ||
SONY | KPR36XBR | Intermittent video, replaced d-5015 | Several units display same problem, found d-5015 was opening. | ||
SONY | CDP110 | Unit may not focus or may not track | Unit may not focus or may not track. power up unit andvisually view lens. if lens is off center or does not seem to have fullfocus travel, the problem is ic-2. when this condition occurs, it wouldbe normal to suspect the driver amps (ic6 and ic7). ho | ||
SONY | DT4 | Unit would not play intermittently; makes chattering noise | Unit would intermittently chatter which sounded like lensfocusing. replaced optical to no avail. found rack was binding and wouldcause gear to slip a tooth. | ||
SONY | KV27HFR | Shutdown when using vcr, resolder c-660 | Set was hooked to zenith vcr. set would operate fine until avcr function was initiated, then set would shutdown. set would work okwith other manufactured vcr. | ||
SONY | KV2729R | Loss of horizontal sync, replace r-512 on a board | After warm-up, set would lose horizontal sync. found resistorr512 changing value when cold would read 300k after warm-up, increased to450k. | ||
SONY | CDPC10 | Dead unit; port expander ic212 | Unit was inoperative when cartridge inserted. m-2 did notoperate. found no data on pins 17, 18, 19. lifted these pins and datawas being supplied. | ||
SONY | D4 | No part number for headphone pcb | Part number missing for h/p jack pcb. this commonly breaks.part number on this small pcb is 1-625-769-11. is this valid? if so,please stock kc as this problem is common. -hq comments: we just received a part number for this pcb from tokyo.the part nu | ||
SONY | SPP80 | No ring | Unit would not ring on incoming calls. | ||
SONY | GENERAL | Ic removal jig (solder iron tip) | Is there an ic removal tip which fits ics cxa1081 (30 pin) andcx20157 (24 pin)? if so, i need part numbers for them. -hq comments: the tips that we have available are listed in generals/b no. 11. none of these fit these particle ics well. however, ot | ||
SONY | CDPC50 | Drawer would not open completely | Drawer would not open completely and was sluggish. foundrunner grove of table had upset about 2/3 to rear. this upset caused drawer to hang up. | ||
SONY | EVC8U | Camera recognition and tally operation | 1) how does the ev-c8u know when a camera is connected?2) is the tally output at camera connector cn807 pin 9 active whenconnecting a line input via the multipin connector? -hq comments: 1) via the serial control bus at camera connector cn807pin 7. 2) | ||
SONY | SLHF300 | Unit will not memorise programmed channels | Unit will not memorise programmed channels when the ss-32board is replaced. | ||
SONY | D170 | No audio | No audio, with no -5v to d/a converter. i have seen thisthree or four times. | ||
SONY | XR170 | Switches from am to fm/am or fm cuts out intermittently | Cmc distributing has several units with fm cutting out andswitching to am. it was found that the main circuit board mounting screwswere loose. the one mounting screw that is located at the left front whenthe unit is upsidedown is the one that is causin |