PHILCO | TP-1452 | TV with normal power supply, when turned on it generates and cuts in 1 second | Check r713 of 1k8 changed | Daniel | |
PHILCO | PC 20R42 | Interference on the screen without video TV has sound | Exchange c301 0.47/35 votes | jaironuess | |
PHILCO | PC- 20R42 ** | TV out of horizontal frequency | Or capacitor 303 of 47/35 votes was exhausted | jaironuness | |
PHILCO | TPF 2941 | It has a power supply but no gun | It fell, it was fixed, the trails worked normally; after two days it broke down, it was left alone in the waiting room | carlos branco | |
PHILCO | PCM2044 | When the TV was turned on, the image was shaking, and when the volume was increased, the image was even more shaky. | I checked the power supply and it was normal, but when I removed the capacitor from the power supply input I realized that it had a bad, rotten leg, the 400v/220mf c905 replaced it and went for a hug | This email address is being protected from spambots. You need JavaScript enabled to view it. | |
PHILCO | PCM1443 | Image blinking as if it were a stand by LED, normal frame, normal voltages, except video voltage; controls inoperative. | R713(100k) open. | Replace r713(100k), device ok. | clayton |
PHILCO | TP1454 | Problem with the colors, it remains without demagnetizing the kinescope. | Check the "epcos" brand component with placement number th 901. this component is connected together with the kinescope coil. | Just replace it with another one and go for the hug!!! | FRANCISCO |
PHILCO | TPF-2901 CP01RL01 | When turned on, it displays a white screen with horizontal retrace lines and seconds later it turns off. | Replacement of the 4r7 r711 that was open. | Marques | |
PHILCO | PCS 2700 | The TV turns off as soon as it was turned on | This TV doesn't oscillate without the fly back and without the deflector so it would be more difficult to discover the defect. | But in this case it was the bad deflector coil that was causing the TV to turn off | heliomar |
PHILCO | TPF 2130 CP 03 | Does not turn on, there is no + 14 vdc pin 1 of ic 905 | Change c 918 open | CARLOS ROCHA | |
PHILCO | PCS-2976 | Actuated protection It is with very high voltage | C715 or c730 changed | Henry Moura | |
PHILCO | PCS 3322N CP 01 LR02 | When turning off the power, it no longer turns on, only flashes, the power supply does not arm | Next to the wide capacitor switch c728 3n3 x 1600v | C728 3n3 x 1600v | This email address is being protected from spambots. You need JavaScript enabled to view it. |
PHILCO | PCM2976 | TV turns on after + or - 30 seconds, threatens to close the horizontal and turns off. | Probable cause, open power supply diode d917. | amsmariano | |
PHILCO | PCM-2046 | Jagged image | Interference on the kinescope PCI flat | Move the kinescope PCI flat away from the flay back as much as possible. | Wender |
PHILCO | DVT 100 | Doesn't spin the disc | R 23 of 1 r | Replace r 23 of 1 r | This email address is being protected from spambots. You need JavaScript enabled to view it. |
PHILCO | PCS2952N | Low power supply hitting the power supply transformer | Diode in4148 901 open | julio itaguai | |
PHILCO | TP2054 | When the TV was turned on, it started to show high voltage and then turned off and did not oscillate | I turned off +b from the flay back and the TV oscillated normally with the 109v input but if I turned on +b it stopped oscillating. | I tested the flay back in my test and it was bad without discharge, I replaced it and everything was fine | This email address is being protected from spambots. You need JavaScript enabled to view it. |
PHILCO PLATINUM | TP1452N | Does not turn on, inoperative, low voltage and oscillating on the horizontal transistor collector. | Change 1uf x 100v electrolytic located in the power supply. | FRANCISCO This email address is being protected from spambots. You need JavaScript enabled to view it. | |
PHILCO | TP1452 | Power supply pulsing, inoperative. | Check the 1uf x 100v electrolytic capacitor at the power supply. Just replace it with another one. | FRANCISCO This email address is being protected from spambots. You need JavaScript enabled to view it. | |
PHILCO | PCS2976S | Horizontal closing on the sides | 150k resistor near d irf ,n fir horizontal plate swap | Replace everything resolved | MARCOS MELO CASCAVEL CE |