SONYTPSL2
Defective motorUnit runs slow.
SONYTCM121
Mechanical modificationWhen customer presses record button with no tape inserted,pressure of record lever assy. against chassis causes the lever retainingportion to break off. since the retainer is part of the chassis assembly,the entire assy would have to be replaced.
SONYTCK55II
Defective remote chipUnit functions jammed in rewind mode voltages on pin 33 was0.37 volts. rewind mode voltage should read 10 volts. voltages ofremote chip pins 9, 5, 11 and 7 were 1.9v also should be 10 volts.remote chip affected total operation of tape deck.
SONYTC755
Cleaning stop microswitchLow playback level off tape, power supply position ok. recordsection checked ok, found playback amp was being muted by q304 and q404.base measure 1.6v all the time. lifted r437, playback level normal.traced 1.6v back into system control ckt., to emitter of q
SONYTAF3A
Pcb labelling incorrectQ103/104/153/154 - 3 and 4 reversed on pcb labelling. -hq comments: thank you for this information.
SONYPT79R
Part number errorI had ordered a power transformer, p/n 1-446-639-00, for usamodel which i copied the number directly out from the service manual. thetransformer that was sent to me was coded with the same number as was themanual but instead it was of 220 volts. later
SONYSTRV25
Error in manualPage 7 procedure 2, error adjust rt101 for 76 khz +/- 100 hz.this is opposite str-v2/-v3/-v4.
SONYSTRV25
Modification on mounting flame proof resistorsQ652 failed causing flame proof resistors r633, 664, 665 tooverheat and open. this type resistor gets very hot before opening sincethese are mounted tight against the board. damage will occur when theyget hot.
SONYSTRV5
Defective ic451No output, meter and lights operating, relay activates. b+and b- low.
SONYSTRV3
Error in service manualThe schematic (page 20) shows bias test points incorrectly atcollector of q713 and q763. should be at emitters. -hq comments: see technical newsletter #8102.
SONYSTRV2
Error in service manualVco adjustment page 9, procedure 2, adjust rt201 for 19khz+/- 100hz error.
SONYICFC310W
Modification for buzzer levelAlarm level very low.
SONYICFC11W
Clean and adjust switchAlarm set time shows upon auto buzzer.
SONYICF7600
Loose dial indicatorDial indicator needle disconnects from the dial string. theunit will continue to tune radio stations but customer is unable to determine the station from the indicator.
SONYCFS71
Lubrication in switch assy neededWhen the fast fwd/rewind switch is activated by the switchlever assy, binding of the two nylon pieces can occur. this causes themuting switch to stay in the on position. the audio is then greatlyreduced. this condition occurs most often when the ams f
SONYCFM23
Defective motorTape speed slowing - occasionally decrease in current tomotor. same decrease on external dc input.
SONYTFM7720W
Broken connection on controlVolume control has no effect on volume - volume remains loud.removed volume control and it was working properly.
SONYTFM7720W
Cold solderNo am on low end.
SONYTFM6160W
Loose pulleyThe tuning dial does not work. the pulley near the speakerpulls loose causing the dial string not to work.
SONYTCS300